產品簡介

9243單/多通道應變信號放大器內置校準

詳細介紹

9243單/多通道應變信號放大器

內置校準,電位分離,可通過DIP開關配置,易于安裝在DIN安裝導軌上,可選防護等級為IP65的版本

  • Features

    • 精度<0.05%
    • 模擬量電壓輸出0... ±5 V或0...±10V或電流輸出0...20mA或4...20mA
    • 可接6線制和4線制傳感器
    • 信號與電源之間的隔離
    • 截止頻率1 kHz,可選配4kHz
    • 通過DIP開關進行配置
    • 易于安裝在DIN安裝導軌上(可選配IP67保護等級)
  • Description

    The amplifier module model 9243 is used wherever measurement signals from strain gauges, potentiometric sensors or DC/DC sensors have to be converted into standard signals. Simply by mounting on conventional DIN-mount rails, it is possible to position the amplifier module on location, in the proximity of the sensor. Especially for rough environments a IP65 version is available.

    The broad auxiliary power range and the choice between AC or DC permits operation on standard power supplies used in switch gear cabinets. A highly precise reference voltage source is built-in for calibration purposes. A calibrating shunt can also be connected via two separate terminals. This permits deliberate detuning of a strain gauge sensor for calibration or merely to check the measuring chain.

    A highly accurate precision amplifier performs the amplification of the sensor signal being applied. The necessary gain factor is adjusted coarsely with DIP switches while fine-tuning is carried out by using a potentiometer. Current and voltage outputs are available simultaneously. The sensor excitation is performed by the amplifier module itself so that no additional voltage source is required. It can also be set in steps of 2.5 V, 5 V, 10 V using DIP switches. The maximum feed current of 35 mA permits parallel connection of several strain gages, e.g. for the addition of measurement variables. Measurement errors brought about by varying line lengths or due to temperature fluctuations effecting the sensor cable are avoided by having probe lines measuring the actual feed voltage directly on site at the sensor itself (6 wire technology). Fluctuations are immediately corrected electronically. The cut-off frequency of the amplifier can be switched between 10 Hz and 1 kHz. The DIP switches for configuring the entire device are found easily accessible, under a cover.

  • Downloads

    Data sheet
    pdf 9243資料參數
    Operation manual
    pdf 9243使用手冊

Related products

Compare product


感興趣的產品PRODUCTS YOU ARE INTERESTED IN

智慧城市網 設計制作,未經允許翻錄必究 .? ? ? Copyright(C)?2021 http://cchxqp518.com,All rights reserved.

以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,智慧城市網對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~