Incoming microwave and PIR signals are constantly monitored and individually qualified for intrusion characteristics. The timing and sequence of each of these signals must be qualified by MAP settings to specific environments, allowing for optimum catch performance and false alarm immunity.
The use of dual technology provides the best detection available while virtually eliminating false alarms and costly service calls.
Allows trouble conditions to be quickly identified, diagnosed and corrected.
360° field-of-view, mounting height from 8' to 16' (2.4m to 4.9m), install as recessed or surface mount.
Microcontroller automatically initiates self-tests at power-up, trouble conditions and programmed intervals.
After a trouble is confirmed with a self-test, the trouble output can be used to annunciate the trouble condition.
– Patented INFORMER® circuit constantly monitors microwave and PIR against blockage and misapplication.
– Independent circuit supervises both microwave and PIR against failure; at a loss of signal, microcontroller initiates self-test and unit switches automatically to single technology operation.
Mounting
Surface or flush mount on ceilings (flush mount kit included); maximum standard range obtained at 11' (3.4m). PIR mirror assembly included for installation on 12' to 16' (3.7m to 4.9m) ceilings.
Model | DT-6360STC |
Physical Dimensions
| White, high impact, ABS plastic housing |
5.0" H x 5.0" W x 2 1/2" D (13cm x 13cm x 6cm) | |
Weight | 14 oz (397 g) |
Power Requirements
| 10 – 12.9 VDC |
40mA, 12 VDC typical | |
Trouble Output | Open collector: voltage between collector and emitter (Vce) is 0.3V @ 50mA |
Alarm Relay | Energized Form C: (N.O./N.C.) reed relay rated 125mA at 25VDC |
Command Output | |
Self-test initiate | |
Active: | 0 – 1.5V (low) |
Inactive: | 6 – V+ (high) |
impedance | 110K (minimum) |
Microwave Frequencies | |
Center band 10.525 GHz (USA) | |
Tamper Switch | |
Ceiling and cover tamper switches; Form A (N.C.) switch rated 25mA, 30VDC | |
Operating Temperature | |
32° – 120° F (0° – 49° C); 5% to 95% relative humidity, noncondensing | |
RFI Immunity | |
30 Vm, from 10 MHz – 1000 MHz | |
PIR White Light Immunity | |
900 LUX | |
Detection Range | |
50' (15m) diameter, 25' (7.6m) radius | |
PIR Fields of View | |
8'–11' mirror assembly (three 360° fields) | |
Long range: 36 | |
Intermediate: 24 | |
Lower: 16 | |
Look-down: 1 | |
12'–16' mirror assembly (two 360° fields) | |
Long range: 40 | |
Intermediate: 20 | |
Look-down: 1 | |
Sensitivity | |
2–4 steps within field of view | |
Approvals/Listings | |
FCC certified, UL listed, DTI approved, CE |